The EasyReader range offers
you user-friendly economy for all your indoor process measurements.
2 sizes, for viewing distances
of 20 metres and 40 metres.
Models for....
- Process measurement
4-20mA and 0-10V DC process signal inputs
- Totalizing, with NPN,
PNP or contact closure inputs
- Rate/frequency/speed
measurement, with NPN, PNP or contact closure inputs
- ASCII data remote display,
with RS232 & RS485 inputs.
- BIG advantages = EASY
to USE + LOW COST!
|
- Smart styling
- Clear,
bright display
- Broad range
of models
- Low maintenance
costs
- Lowest cost
large display
- Fast, free technical
support
- High immunity
to interference
- Easy to use,
menu-free setup
- Lockout system
to save your settings
- Can be configured
from the front panel
- Long warranty,
extendable free of charge
|
4 Input Signal
types
4-20mA, 0-10V, 1-5V etc
Pulses PNP, NPN, Contact etc
Serial Data RS232, 485, 422 etc.
BCD data, via model PSC1
2 digit sizes
57 mm for up to 25 metres viewing
102mm for up to 50 metres viewing
|
10 Display Functions
- Total
- Rate
- Process
- Weight (with
amplifier or weigh-head)
- Slave display
from RS232, RS485 etc.
- Frequency
- Temperature
(with external converter)
- Humidity (with
external converter)
- Power (with
external converter)
- Pressure
|
A simple and affordable
way to easily see and share important
measurements over distances up to 50 metres.
Help your workforce to keep in touch with what is happening
.
Measurements can be seen up to 50 metres away. Ideal for
displaying your important plant variables such as:-
* Production rate - are we working fast enough?
* Production total and target - have we made enough?
* Temperature and humidity in controlled environments
* Crane lifting weight - are we within safe limits?
* Weighbridge load - the driver can stay in his cab.
* Any physical variable important to your process |
Specification:
Models
ER2P and ER4P
Ranges 4-20mA, 0-10V and 1-5V DC as standard, fully scalable.
Scaling method INTUITIVE menu-free digital scaling. Settings stored
in non volatile memory.
Input resistance 33 Ohms for current inputs, 1 Megohm for voltage
inputs.
Excitation 24VDC nominal, at up to 30mA
Accuracy +/- 0.1% of range +/-1 count at 25C. Tempco +/-100ppm/C
zero and span.
Read-rate 3 per second nominal
Filtering Signal averaging period adjustable from 0 to 5 seconds
Count-by Can be set to count by 1,2,5,10,20 or 50
Features Tare, Peak, Valley and reset from front panel or with remote
contact closures
Models ER2C and ER4C
Signal types NPN, PNP or contact closure, from proximity sensors,
switches, relays etc.
Functions Counting and pulse rate, fully scalable.
Scaling method INTUITIVE menu-free digital scaling. Settings stored
in non volatile memory.
Excitation 24VDC nominal, at up to 50mA
Accuracy(rate) +/- 0.05% of range +/-1 count at 25C. Tempco +/-50ppm/C
zero and span.
Read-rate 3 per second nominal
Filtering(rate) Signal averaging period adjustable from 0 to 5 seconds
Features Peak, Valley and reset from front panel or with remote
contact closures
Models ER2S and ER4S
Signal types ASCII data from 300 to 9600 baud. RS232, RS485, RS422
and TTY types.
Addressing From 00 to FF
Protocol Adjustable to suit a wide range of data sources.
Accuracy Precise copy of incoming data.
Read-rate Display updates with each incoming data string.
Features Tare, Peak, Valley and reset from front panel or with remote
contact closures
Materials:
Case uPVC welded extrusion
Lens Anti-reflective tinted acrylic
Environment:
Working temperature 0 to 50 degrees C
Storage temperature -20 to +70 degrees C
Humidity 0 to 95 %rh non condensing
Sealing IP54 dust tight
Atmosphere Non-flammable, non explosive
Download EasyReader Datasheet
|