Measurement, Control & Data Acquisition
 
 

Request a Quotation
Click here to send us your inquiry for our immediate attention

Or call us now on
+44 (0)8700 434040

Call us free on Skype:
omni-info

 

Order a Catalogue

Download our free engineering
 units converter !

 

UK / Europe Office
Tel +44 (0)8700 43 40 40
Fax +44 (0)8700 43 40 45

info@omniinstruments.co.uk

East Kingsway Business Centre
Mid Craigie Trading Estate,
Mid Craigie Rd, Dundee,
DD4 7RH, Scotland, UK
 
 
USA / Canada Office
Tel +1-866-849-3441
Fax +1 866 628 8055
info@omniinstruments.net
www.omniinstruments.net
 
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au

www.omniinstruments.com.au


we also accept purchasing cards

 

Level

Instrument Hire

Gyros, Accelerometers & IMU'S

Gas Detectors

Test & Calibration Air Flow & Environmental Chart Recorders

Terms & Conditions

news / new products

links

Elpro 105U-G
Wireless connectivity between different FieldBus protocols - Profibus, Ethernet, Modbus, DF1, DeviceNet, Modbus Plus.

Interface between Wireless I/O and DCS/PLC/HMI

The 105U-G Wireless gateway products provide a wireless interface between various data buses used in process and automation applications. The 105U-G includes an integral radio transceiver, and transfers transducer and control signals (I/O) using a highly secure and highly reliable radio protocol.

The 105U radio protocol is designed for very efficient radio usage, with configurable communications based on event reporting (I/O change), update times and/or poll response. Other features are:

  • high security data encryption
  • automatic acknowledgment and error-correction,
  • peer to peer addressing, and
  • mulitple path routing

Applications include:

  • The 105U-G interfaces between 105U wireless I/O and various data buses. Connect wireless I/O to PLC's, DCS, SCADA or Internet.
  • Wireless extension of factory automation buses such as Profibus and Ethernet.
  • Wireless interconnectivity between different data buses - Ethernet to Profibus to Modbus to DF1.

Elpro Radio Telemetry

The 105U-G modules also have eight on-board discrete I/O, individually configurable as input or output.

Network configuration is performed with easy-to-use free software. I/O links are configured between different modules in the network.

Ordering information:

105U-G-MD1 Modbus Master, Modbus Slave, DF1 interface
105U-G-PR1 Profibus DP Slave interface
105U-G-ET1 Ethernet IP / Modbus TCP / HTTP-FTP-Email
105U-G-DE1 DeviceNet Slave interface
105U-G-M+1 Modbus Plus Slave interface

Specifications

Power Supply

  • 9 - 30VDC / 12 - 24VAC
  • Battery charging circuit included for 12V back-up battery, max charge current regulated to 1A
  • Normal current drain
  • Modbus / DF1 version 12V 150mA; 24V 90mA
  • Profibus / Ethernet 12V 270mA; 24V 170mA
  • Add 5mA per active I/O
  • Current drain during radio transmission - add to above
  • 12V 350mA; 24V 200mA

General

  • Modbus/DF1 version
       -20 to 60 degC, 0 - 99 %RH
  • Profibus / Ethernet / DeviceNet / Modbus Plus
       0 to 60 degC, 0 - 95 %RH
  • EMC Compliant EN55022, EN50082-1, FCC Part 15
  • Housing - extruded aluminium case 130 x 185 x 60 mm, DIN rail mounting, removable terminal blocks for ease of module replacement, terminals suitable for 2.5sqmm wire
  • LED indication for processor OK, radio TX and RX, serial TX and RX, active status.

I/O Capacity

  • Modbus / DF1 4300 I/O points (analog plus discrete)
  • Profibus 416 I/O bytes
       up to 1952 discrete inputs / 1952 discrete outputs
       or up to 122 analog in / 122 analog out
  • Ethernet 2048 bytes input and 2048 bytes output
       up to 4300 discrete I/O points
       or up to 1024 analog in / 1024 analog out
  • DeviceNet 512 bytes input and 512 bytes output
       up to 4300 discrete I/O
       or up to 256 analog in / 256 analog out
  • Modbus Plus 2048 bytes input and 2048 bytes output
       up to 4300 discrete I/O
       or up to 1024 analog in / 1024 analog out
  • Register size 16 bit
  • Number of remote 105U addresses 500

Radio Transceiver

  • Single channel, synthesised, direct frequency modulation.
  • Frequency 405-490 MHz, 12.5KHz channels, 10-500mW, 5W
                   220-230 MHz, 25KHz channels, 5W
                   869.525 MHz, 250KHz channel, 500mW
  • Approved to EN 300 220, AS4268.2, RFS29
  • Expected line-of-sight range, with unity gain antennas
       10mW - 2km; 500mW - 5km(869Mz) / 10km (400MHz);
  • 5W - 40km (220MHz) / 30km (400MHz)
  • Range may be extended by up to four intermediate repeaters.

Radio Transmission

  • Radio communications can be configured for combination of event reporting (change-of-value), update time, read/write blocks and poll response.
  • Radio message includes system addressing, unit addressing, error-checking and configurable security encryption.
  • Communication control includes message acknowledgments and up to four re-transmissions.
  • Peer to peer addressing. Messages may be routed thru four intermediate repeater addresses.
  • Fail-to-transmit and fail-to-receive alarms configurable

Modbus Specification

  • Modbus RTU (binary), master / slave configurable.
  • RS232 or RS485, 300 - 19200 bits/sec.

DF1 Specification

  • Allen-Bradley DF1 full-duplex.
  • RS232 only, 300 - 19200 bits/sec.

Profibus

  • Profibus-DP Slave functionality according to EN 50170.
  • RS-485 optically isolated with on-board DC/DC converter, automatic baudrate detection (9600 bit/s - 12 Mbit/s)

Ethernet

  • 10/100 Mbit/s, RJ45 transformer isolated interface
  • Modbus/TCP class 0, class 1 and partially class 2 slave
  • EtherNet/IP level 2 I/O Server
  • Embedded Web system (Dynamic HTTP), on-board file system (1.4MB flash disc), user downloadable web pages through FTP server, Email functionality (SMTP)

DeviceNet

  • DeviceNet 2.0 Slave, optically isolated RS422 with selectable baudrate 125, 250 and 500 Kbit/sec.

Modbus Plus

  • Modbus Plus Slave, optically isolated RS485 with standard baudrate of 1 Mbit/sec, global data base transactions with routing for up to six networks.

On-board I/O

  • Eight discrete I/O, individually configurable as input or output. Inputs suitable for voltage free contacts.
  • Outputs are FET, 30VDC 500mA.

Configuration & Diagnostics

  • Configuration via free Windows software
  • Diagnostics include on-line read/write of I/O registers, radio signal strength values from remote units, and off-line testing of data bus protocol.

Level

Instrument Hire

Gyros, Accelerometers & IMU'S

Gas Detectors

Test & Calibration Air Flow & Environmental Chart Recorders

Terms & Conditions

news / new products

links

Measurement, Control & Data Acquisition
 
 

Request a Quotation
Click here to send us your inquiry for our immediate attention

Or call us now on
+44 (0)8700 434040

Call us free on Skype:
omni-info

 

Order a Catalogue

Download our free engineering
 units converter !

 

UK / Europe Office
Tel +44 (0)8700 43 40 40
Fax +44 (0)8700 43 40 45

info@omniinstruments.co.uk

East Kingsway Business Centre
Mid Craigie Trading Estate,
Mid Craigie Rd, Dundee,
DD4 7RH, Scotland, UK
 
 
USA / Canada Office
Tel +1-866-849-3441
Fax +1 866 628 8055
info@omniinstruments.net
www.omniinstruments.net
 
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au

www.omniinstruments.com.au


we also accept purchasing cards