Process Displays \ Multi Channel Process Indicators \ SRD-99 Multi-Channel Display & Data Logger

 

«« previous product   2 / 3   next product »»

SRD-99 Multi-Channel Display & Data Logger

The SRD-99 Multi-channel display is designed to record signal inputs and display current values in graphs and numeric form. The device is equipped with 1, 4 or 8 temperature (Pt100/500/1000) or current (in the 0/4-20 mA standard) inputs, one pulse (digital) input for controlling the recording process, two relay outputs for control and one USB Host port for flash data storage.
 
 
 
 

1 Week Del.

 
 
Downloads

Send page to a colleague

 

 
 

Product details

 
The device has the memory capacity of 2 MB (0.5 million data recordings altogether) or 8 MB in version with USB port (2 million data recordings). However when a USB flash drive is plugged permanently, it can significantly extend the recording time without a need of data transferring from SRD-99 to a PC. For example: 1GB flash drive allows continuous data recording for over 1 year (8 channels recorded every 1 sec., approx 250 millions data recordings)!The logging rate is programmable from 1 second to 60 minutes.

The internal analogue-digital converter has a 16 bit resolution (12 bit in unit with 0/4-20mA inputs), which provides high recording resolution results. Additionally, individual alphanumeric description (text) of each of the recorded channels is possible. The menu assisted with full text descriptions makes the unit configuration process quite easy. However, due to a significant number of configured parameters it is advised to use the attached configuration software for PCs.

Specifications
  • Power supply voltage: 19V ÷ 50V DC, 16V ÷ 35V AC or 85 ÷ 260V AC/DC
  • Power consumption: typical 7 VA; max. 12 VA
  • Display: graphic LCD, 128 x 64 points, with backlight
  • Measuring inputs: 1, 4 or 8, Pt100; Pt500; Pt1000 (2 and 3-conductor connection) or 0/4-20 mA inputs; common earthing
  • Sample Rate Programmable 1 second to 60 minutes
  • Logging Modes Stop when full or memory wrap
  • Measuring range: ± 9999 + decimal point (current inputs); -100°C +600°C (RTD inputs) with resolution 0,1°C
  • Digital input: 1 input 24V DC
  • Sensors supply: 24 V DC±5% / 200 mA, not separated from measuring inputs
  • Communication interface:  RS-485 (MODBUS RTU) or USB Host port, galvanically separated
  • Transmission speed: 1200 - 115200 bit/sec.
  • Memory capacity: 2 MB (0,5 milion data recordings) 8 MB (above 2 milion data recordings) in version with USB Host
  • Protection: version without USB: IP 40 (front side) IP 65 (front side when an additional frame is installed)
  • Protection: version with USB: IP 20, IP 42 (when transparent door with security key type STD-99 is installed)
  • Working temperature: 0°C ÷ +60°C
  • Storage temperature: -10°C ÷ +70°C
  • Case dimensions:  96 x 96 x 100 mm
  • Panel cut-out dimensions: 90,5 x 90,5 mm
  • Installation depth: min. 102 mm
  • Board thickness: max. 5 mm
 

Part Builder

Description
SRD-99 data logger with LCD display, with large digit, graph and table view, one pulse (digital) input for controlling the recording process, RS485, programmable logging rate 1 second - 60 minutes
Price
$ 412.24
 
Options
Please select your preference for all the options shown and click on 'Build Part No'. The full unit description will be shown above with the part number and the price. If you wish to change any of the options use the delete button, make a new selection and then click on the 'Build part No' again.
Channels
Input Type
Power Supply
Options
Transparent Door
Quantity
 
 

Components / Downloads

 
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
 

ref

description

downloads

price ($)

Order Item

SRD-99

1 to 8 channel recorder with 4..20mA/RTD inputs, USB memory port, RS485 port, PC software, power supply 85-260VAC . Int. mem 2M rdgs

 

Datasheet

 

0.00

Not Available online

 
 
 


 
+44 (0) 845 9000 601
    +44 (0) 845 9000 602
    info@omni.uk.com
+1-866-849-3441
    +1-866-628-8055
    info@omniinstruments.net
+61 (0)282 442 363
    +61 (0)294 751 278
    info@omniinstruments.com.au
Copyright � 2009 - Omniinstruments Home | About Us | News / New Products | Old Omni Site | Terms and Conditions | Links | Sitemap | Web Design