Gas Detection Equipment \ Gas Detection Systems \ MX 48 8 Channel Alarm / Display unit

 

лл previous product   5 / 5  

MX 48 8 Channel Alarm / Display unit

MX 48 8 channel alarm/display unit with fixed or scrolling display, 3 programmable alarm thresholds per channel, fault alarm, analogue and serial outputs.
 
 
 
 

 

 
 

Product details

 

The MX 48 is designed to protect your equipment and personnel in environments liable to contain flammable or toxic gases.

Equipped with up to 8 independent channels, the MX 48 can be used to control different types of detectors. In fact, this unit is compatible with all the detector tramsmitters in the OLDHAM range and any detector with a standard 4 - 20 mA output.

 

MX 48: designed to meet your needs

The MX 48 caters for a wide range of possible uses, adapting to your safety requirements.

The variety of programming options, by keypad or computer, ensures that it is perfectly adaptable to specific user needs. Furthermore, the MX 48 is open - ended, so that, if required, subsequent extensions or modifications can be added.

Easy to install and very flexible to use, the MX 48 can handle a large quantity of applications to cater for your technical requirements at lower costs.

MX 48 : MEASUREMENT AND ALARM UNIT

The MX 48 is designed for prevention, action and detection, it :

    • monitors detectors
    • displays the nature, concentration, measurement and unit of the gas detected (in cyclic mode)
    • triggers alarms if the measurement exceeds thresholds
    • actuates relays for the control warning devices, valves and mimic panels
    • indicates faults
    • transmits data via analogue and serial outputs.
  • COMPLIANT WITH EUROPEAN STANDARDS
    • European standards EN 50054, 50081, 50082 and low voltage directives.

 

Enhanced ergonomics and performance

  • USER - FRIENDLY DISPLAY PANEL
  • TRIPLE ALARM LEVEL
    • 3 individually adjustable alarm levels
    • Alarms 1 and 2 instantaneous or governed by control logic of 2 speed ventilation systems
    • Alarm 3 time - delayed or based on mean calculation
    • Local or remote acknowledgement, useful in control room
  • SIMPLE OPERATION
    • 4 - 20 mA input so that any type of standard detector can be connected, in addition to OLDHAM detectors
    • Common serial output in J-BUS format and analogue outputs per channel
    • Management of failures and alarms by micro - controller and internal software
  • GREATER RELIABILITY
    • Fault monitoring
    • Possibility of transmission of audio alarm to the detection site
    • Testing of indicator lights and integrated display panel
    • Transmission of measurements, alarms, failures and relay status via RS232 or 485 output for each channel
    • Relays programmed in positive or negative safety mode
    • Inhibition of relays in maintenance mode of limited duration and signalled by an indicator light
  • HIGH SAFETY UNIT
    • Efficient protection against radio frequencies and industrial interference, to avoid false alarms in environments subject to electrical interference (EMC compliance)
    • Integrated protection against human operating errors
    • Protected access to programming.
Technical Characteristics
Manufacturer Oldham SA Link 2 or 3 wires, active, with display according to type of detector
       
Presentation Wall mounted box Resistance  
Function Gas monitor In Loop Mode Flammable, 3 wires: 32 ohm
Capacity Up to 8 channels   4 - 20mA: 2 or 3 wires: 56 ohm
Display Fluorescent, 2 lines of 16 characters   Average line length (in meters at 20C for a 2.2m2 conductor)
  Fixed or scrolling   Flammable: 1000m / 4-20mA: 2000m
Alarms   Signal Output Analogue 4-20mA per channel, load resistance: 600 ohm max.
Fault Alarm Yellow LED on each channel   Serial RS485 or 232 in J-BUS format, opto-insulation on option
  Action on common relay Power Supply 109 to 122v AC or 207 to 244v AC
Gas Alarm 3 independent thresholds per channel (red LED's)   21 to 31v DC
  3rd threshold time delayed or mean value   Power consumption: 200vA or 150W
  Manual or automatic reset Miscellaneous Acknowledgement: local or remote
  2 relay outputs per channel, common relay on alarm 3   Operating temperature: -20C to +55C
Audio Alarm 80db at 30cm   Relative humidity 5% to 95%, uncondensed
Relay Output 2 gas alarm relays per channel   Compliant with European standards 50054, 50081 50082, AFAQ ISO 9001
  1 common failure relay for alarm 3 Protection IP 65
  Programmable positive or negative safety on alarm relay Weight 11Kg
  Positive safety on failure Dimensions H 340 x W 500 x D 89mm
  Programmable NO or -NC    
Measurement Input      
Type of Detectors Flammable bridge type    
  Flammable transmitter, toxic or oxygen detector (type 4-20mA)    
       
 

Components / Downloads

 
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
 

ref

description

downloads

price($)

Order Item

W480820

MX48 Gas Detection Panel, 4 Channels

 