Radio & GSM Telemetry \ Radio Telemetry Systems \ Elpro 105U-G Wireless Protocol Telemetry Modems

 

лл previous product   6 / 6  

Elpro 105U-G Wireless Protocol Telemetry Modems

The 105U-G offer wireless connectivity between different data buses - Profibus, Ethernet, Modbus, DF1, DeviceNet, Modbus Plus with more options available in the future. Feature eight, discreet digital I/O induvidually configurable as input or output. Wireless Instrumentation Backbone (WIB) allows direct communication to other Elpro 105U and 505U telemetry units.
 
 
 
 

 

 
 

Product details

 
Wireless connectivity between different FieldBus protocols - Profibus, Ethernet, Modbus, DF1, DeviceNet, Modbus Plus.

Interface between Wireless I/O and DCS/PLC/HMI

The 105U-G Wireless gateway products provide a wireless interface between various data buses used in process and automation applications. The 105U-G includes an integral radio transceiver, and transfers transducer and control signals (I/O) using a highly secure and highly reliable radio protocol.

The 105U radio protocol is designed for very efficient radio usage, with configurable communications based on event reporting (I/O change), update times and/or poll response. Other features are:

  • high security data encryption
  • automatic acknowledgment and error-correction,
  • peer to peer addressing, and
  • mulitple path routing

Applications include:

  • The 105U-G interfaces between 105U wireless I/O and various data buses. Connect wireless I/O to PLC's, DCS, SCADA or Internet.
  • Wireless extension of factory automation buses such as Profibus and Ethernet.
  • Wireless interconnectivity between different data buses - Ethernet to Profibus to Modbus to DF1.

 

The 105U-G modules also have eight on-board discrete I/O, individually configurable as input or output.

Network configuration is performed with easy-to-use free software. I/O links are configured between different modules in the network.

Ordering information:

105U-G-MD1 Modbus Master, Modbus Slave, DF1 interface
105U-G-PR1 Profibus DP Slave interface
105U-G-ET1 Ethernet IP / Modbus TCP / HTTP-FTP-Email
105U-G-DE1 DeviceNet Slave interface
105U-G-M+1 Modbus Plus Slave interface

Specifications

Power Supply

  • 9 - 30VDC / 12 - 24VAC
  • Battery charging circuit included for 12V back-up battery, max charge current regulated to 1A
  • Normal current drain
  • Modbus / DF1 version 12V 150mA; 24V 90mA
  • Profibus / Ethernet 12V 270mA; 24V 170mA
  • Add 5mA per active I/O
  • Current drain during radio transmission - add to above
  • 12V 350mA; 24V 200mA

General

  • Modbus/DF1 version
       -20 to 60 degC, 0 - 99 %RH
  • Profibus / Ethernet / DeviceNet / Modbus Plus
       0 to 60 degC, 0 - 95 %RH
  • EMC Compliant EN55022, EN50082-1, FCC Part 15
  • Housing - extruded aluminium case 130 x 185 x 60 mm, DIN rail mounting, removable terminal blocks for ease of module replacement, terminals suitable for 2.5sqmm wire
  • LED indication for processor OK, radio TX and RX, serial TX and RX, active status.

I/O Capacity

  • Modbus / DF1 4300 I/O points (analog plus discrete)
  • Profibus 416 I/O bytes
       up to 1952 discrete inputs / 1952 discrete outputs
       or up to 122 analog in / 122 analog out
  • Ethernet 2048 bytes input and 2048 bytes output
       up to 4300 discrete I/O points
       or up to 1024 analog in / 1024 analog out
  • DeviceNet 512 bytes input and 512 bytes output
       up to 4300 discrete I/O
       or up to 256 analog in / 256 analog out
  • Modbus Plus 2048 bytes input and 2048 bytes output
       up to 4300 discrete I/O
       or up to 1024 analog in / 1024 analog out
  • Register size 16 bit
  • Number of remote 105U addresses 500

Radio Transceiver

  • Single channel, synthesised, direct frequency modulation.
  • Frequency 405-490 MHz, 12.5KHz channels, 10-500mW, 5W
                   220-230 MHz, 25KHz channels, 5W
                   869.525 MHz, 250KHz channel, 500mW
  • Approved to EN 300 220, AS4268.2, RFS29
  • Expected line-of-sight range, with unity gain antennas
       10mW - 2km; 500mW - 5km(869Mz) / 10km (400MHz);
  • 5W - 40km (220MHz) / 30km (400MHz)
  • Range may be extended by up to four intermediate repeaters.

Radio Transmission

  • Radio communications can be configured for combination of event reporting (change-of-value), update time, read/write blocks and poll response.
  • Radio message includes system addressing, unit addressing, error-checking and configurable security encryption.
  • Communication control includes message acknowledgments and up to four re-transmissions.
  • Peer to peer addressing. Messages may be routed thru four intermediate repeater addresses.
  • Fail-to-transmit and fail-to-receive alarms configurable

Modbus Specification

  • Modbus RTU (binary), master / slave configurable.
  • RS232 or RS485, 300 - 19200 bits/sec.

DF1 Specification

  • Allen-Bradley DF1 full-duplex.
  • RS232 only, 300 - 19200 bits/sec.

Profibus

  • Profibus-DP Slave functionality according to EN 50170.
  • RS-485 optically isolated with on-board DC/DC converter, automatic baudrate detection (9600 bit/s - 12 Mbit/s)

Ethernet

  • 10/100 Mbit/s, RJ45 transformer isolated interface
  • Modbus/TCP class 0, class 1 and partially class 2 slave
  • EtherNet/IP level 2 I/O Server
  • Embedded Web system (Dynamic HTTP), on-board file system (1.4MB flash disc), user downloadable web pages through FTP server, Email functionality (SMTP)

DeviceNet

  • DeviceNet 2.0 Slave, optically isolated RS422 with selectable baudrate 125, 250 and 500 Kbit/sec.

Modbus Plus

  • Modbus Plus Slave, optically isolated RS485 with standard baudrate of 1 Mbit/sec, global data base transactions with routing for up to six networks.

On-board I/O

  • Eight discrete I/O, individually configurable as input or output. Inputs suitable for voltage free contacts.
  • Outputs are FET, 30VDC 500mA.

Configuration & Diagnostics

  • Configuration via free Windows software
  • Diagnostics include on-line read/write of I/O registers, radio signal strength values from remote units, and off-line testing of data bus protocol.
 

Components / Downloads

 
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
 

ref

description

downloads

price($)

Order Item

ELP-105U-G-MD1

Elpro 105U-G-MD1 radio telemetry unit, with modbus communications, 8 x digital I/O channels, power supply 240vAC or 12 - 30 vDC, 150mA Idle 350mA transmitting.

 

Data Sheet

 