Level

Instrument Hire

Gyros, Accelerometers & IMU'S

Gas Detectors

Test & Calibration Air Flow & Environmental Chart Recorders

Terms & Conditions

news / new products

links

34203A Triple Axis MEMS Accelerometer

Precision Aligned ±1 g to ±5 g
Triaxial Accelerometer with Signal Conditioning and Temperature Sensor

Technical Data*

Precisely Measure Real-World Accelerations

[Picture of 34203A Triaxial Accelerometer]

The Summit Instruments 34203A accelerometer has each mutually orthogonal axis precisely aligned within 3/4 degree of the theoretical ideal. This provides the accuracy required by most linear and angular measurement applications without any compensation. Critical applications requiring higher accuracy can use the alignment data provided on the optional calibration certificate to compensate for any small residual error.

Unregulated +8 to +30V DC power is all that is required to measure ±1 g, ±1.5 g, ±2 g, ±2.5 g, ±3 g, ±4 g, or ±5 g accelerations on each of three axes.

Each axial sensor has been tested over the -40 to +85°C temperature range and has a nominal full scale output swing of ±2 volts. The zero g output level is nominally +2.5 volts. Precise values for each axis are available on an optional calibration certificate. Custom versions of the 34203A can be provided for applications which require different ranges and/or bandwidths.


Features and Benefits

  • Precision Alignment
    Each Axis of the 34203A is precision aligned to minimize errors due to axis misalignment or transverse sensitivity.
  • High Accuracy and Linearity over Wide Temperature Range
    The voltage output for each axis of the 34203A is directly proportional to the acceleration along that axis. Each DC-coupled output is fully scaled, referenced, and temperature compensated. Accuracy is improved by minimizing variations due to temperature and aging effects, resulting in a sensor that is more stable over temperature than piezoelectric or piezoresistive devices. Critical applications can use the built-in temperature sensor to compensate for residual temperature effects.
  • Calibration Certificate
    Each 34203A can be supplied with an optional calibration certificate listing gain, offset, and on-axis and transverse alignment parameters needed to ensure rapid and efficient system implementation. The alignment data can be used to compensate the measured values to achieve an even higher level of sensor accuracy.
  • Self-Test on Digital Command
    A TTL-compatible self-test input causes a simulated acceleration to be injected into all three sensors to verify channel integrity.
  • Small Size
    Complete conditioned triaxial accelerometer in less than a cubic inch.
  • Built-in Power Supply Regulation
    Unregulated DC power from +8 to +30 volts is all that is required to measure accelerations on all axes. The 34203A is ideal for automotive applications with the ability to survive both continuous reverse battery to -20V and load dump transients to +60V.
  • Suitable for Harsh Environments
    The 34203A is robust and can be used in harsh environments. The unit will survive 500 g powered and 1000 g unpowered.

Specifications

 

Ta = Tmin to Tmax, 8 <= Vs <= 30 V, Acceleration = 0 g, unless otherwise noted.   

                                                                                  

Parameter                    Min    Typ    Max   Units   Conditions/Notes          

                                                                                  

Range                                                                             

 Measurement Full Scale        ±1            ±5    g     On each axis             

                                                          Must specify via -Rnnn  

 Shock survival, powered     -500          +500    g     Any axis for 0.5 ms      

                                                          Recovers on power cycle 

 Shock survival, unpowered  -1000         +1000    g     Any axis for 0.5 ms      

                                                                                  

Sensitivity                                                                       

 At 25°C, ±5 g FSR                  450¹          mV/g   Precise values on        

                                                          -C001 cal certificate   

 Drift Tmin to Tmax                 ±0.5           %     % of sensitivity at 25°C 

                                                                                  

Zero G Bias Level                                                                 

 At 25°C                    1.875         3.125    V     Precise values on        

                                                          -C001 cal certificate   

 Drift Tmin to Tmax                 ±0.2           g     Repeatable,              

                                                          can be compensated      

Alignment                                                Precise values on        

                                                          -C001 cal certificate   

 Deviation from ideal axes         ±0.15  ±0.75 degrees  Can be compensated       

                                                                                  

Transverse Sensitivity              0.25           %     Inherent sensor error,   

                                                          excluding misalignment  

Nonlinearity                         0.2         % FSR   Best fit straight line   

Upper Cutoff Frequency        4.6         10000    Hz    ±10% Must specify -Bnnn  

Noise                                                                             

 Density                           0.225  0.325    mg    4 Hz to 1 kHz            

                                                sqrt(Hz)                          

 Amplitude DC to 100Hz              2.25         mg rms                           

                                                                                  

Self Test Input Impedance      30     50          kOhm   To ground                

                                                                                  

Temperature Sensor                                       Precise values on        

                                                          -C002 cal certificate   

 Sensitivity                           8         mV/°K   Vt at -40°C = 1.92V nom; 

                                                          Vt at +85°C = 3.16V nom 

 +25°C Bias Level             2.4           2.6    V                              

                                                                                  

Outputs                                                                           

 Voltage Swing               0.05          4.95    V     Iout = ±0.5 mA           

 Capacitive Drive Capability 1000                  pF                             

                                                                                  

Power Supply (Vs)                                                                 

 Input voltage limits         -20           +60    V     -20V continuous,         

                                                          >30V if <100ms,duty <1% 

 Input voltage - operating     +8           +30    V                              

 Input current                         8     12    mA    No load, quiescent       

 Rejection Ratio               80    120           dB    DC                       

                                                                                  

Temperature Range (Ta)        -40           +85   °C                              

                                                                                  

Mass                                  35         grams   -M001 reduces mass to 25g 

                                                                                  

 ¹Scale linearly with range option Rnnn.                                          


Connections

[34203A Triaxial Accelemeter Connector]

 

 Pin        1       2       3       4       5       6       7       8        9    

 Signal    A1+   Signal-   A2+   +5VOut    A3+      T+   SelfTest  +Vs      Gnd   

 Wire     Brown    Red   Orange  Yellow   Green    Blue   Violet   Grey    White  


Mechanical

[34203A Triaxial Accelemeter Dimensions]

34203A Data Sheet

Level

Instrument Hire

Gyros, Accelerometers & IMU'S

Gas Detectors

Test & Calibration Air Flow & Environmental Chart Recorders

Terms & Conditions

news / new products

links

Measurement, Control & Data Acquisition
 
 

Request a Quotation
Click here to send us your inquiry for our immediate attention

Or call us now on
+44 (0)8700 434040

Call us free on Skype:
omni-info

 

Order a Catalogue

Download our free engineering
 units converter !

 

UK / Europe Office
Tel +44 (0)8700 43 40 40
Fax +44 (0)8700 43 40 45

info@omniinstruments.co.uk

East Kingsway Business Centre
Mid Craigie Trading Estate,
Mid Craigie Rd, Dundee,