Measurement, Control & Data Acquisition
 
 

Request a Quotation
Click here to send us your inquiry for our immediate attention

Or call us now on
+44 (0)8700 434040

Call us free on Skype:
omni-info

 

Order a Catalogue

Download our free engineering
 units converter !

 

UK / Europe Office
Tel +44 (0)8700 43 40 40
Fax +44 (0)8700 43 40 45

info@omniinstruments.co.uk

East Kingsway Business Centre
Mid Craigie Trading Estate,
Mid Craigie Rd, Dundee,
DD4 7RH, Scotland, UK
 
 
USA / Canada Office
Tel +1-866-849-3441
Fax +1 866 628 8055
info@omniinstruments.net
www.omniinstruments.net
 
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au

www.omniinstruments.com.au


we also accept purchasing cards

 

Level

Instrument Hire

Gyros, Accelerometers & IMU'S

Gas Detectors

Test & Calibration Air Flow & Environmental Chart Recorders

Terms & Conditions

news / new products

links

1/2/35203A Single/Dual and Triple Axis Smart Accelerometers

Platinum Series
User Configurable 0 to ±5 g
Smart Accelerometer Systems

Technical Data*


Inertial Measurements Made Fast and Easy

[Picture of Platinum Series Smart Accelerometer System]

Summit Instruments Platinum Series Smart Accelerometer Systems are complete, easy-to-use, user-configurable Acceleration Measurement Systems containing one, two or three accelerometers, a temperature sensor, signal processor, IRIG-106 PCM encoder, RS485 interface and three analog outputs in a small, easy-to-install package.

All channels are sampled simultaneously to avoid data skewing. The digital signal processor takes 16-bit samples, filters, ranges, and calibration compensates at up to 42,500 samples/sec/channel. Digital data can be streamed out at up to 3 Mbit/sec.

The output range, filter frequency and calibration of each channel, as well as telemetry configuration, can be set by the user via the RS485 command processor. CRC-16 error checking is used to ensure command and data integrity.

The built-in temperature sensor can be used by critical applications to correct for any residual temperature effects.


Features and Benefits

  • User Configurable Settings
    The analog/digital output range and low-pass filter of each Platinum Series accelerometer axis can be set via built-in RS485 interface as can optional IRIG-106 encoded PCM output settings (channel word, subcommutation, word size, NRZ-L/RNRZ-L/Bi-Phase-L/RBi-Phase/RS485 encoding).
  • Compensated Serial, Telemetry and Analog Outputs
    Calibrated, ranged and filtered data can be streamed out at up to 3Mbit/sec via RS485 or IRIG-106 encoded PCM. Analog output of up to three calibrated, ranged and filtered channels are provided for compatibility with existing systems.
  • High Accuracy and Linearity over Wide Temperature Range
    Accelerometer accuracy is improved by minimizing variations due to temperature and aging effects. Each axial sensor has been tested over the -40 to +85°C temperature range.
  • Built-in Calibration
    Calibration data for each sensor is maintained in the accelerometer.
  • Self-Test
    Self-test commands help verify channel integrity and wiring connections.
  • Small Size
    Complete conditioned uniaxial/biaxial/triaxial accelerometer with digital signal processing in two cubic inches.
  • Built-in Power Supply Regulation
    Unregulated DC power from +8 to +30 volts is all that is required to measure accelerations on all axes. Platinum Series Smart Accelerometer Systems are ideal for automotive applications as they survive both continuous reverse battery to -20V and load dump transients to +60V.
  • Easy Installation with Minimal Wiring Requirements
    A built-in terminal block or cable with 9-pin connector simplifies wiring. Wiring can be minimized by daisy-chaining the two multidrop RS485 pins on up to 30 Platinum Series Smart Accelerometer Systems. Tapped holes on bottom and back simplify horizontal or vertical mounting.
  • Suitable for Harsh Environments
    Platinum Series Smart Accelerometers are robust and can be used in harsh environments, they survive 500 g powered and 1000 g unpowered.
Specifications

 

Ta = Tmin to Tmax, Acceleration = 0 g, unless otherwise noted.                    

                                                                                  

Parameter                    Min    Typ    Max   Units   Conditions/Notes          

                                                                                  

Accelerometer(s)                                                                  

 Maximum Full Scale Range     ±5     ±7            g     On each axis,            

                                                          User configurable       

                                                                                  

 Sensitivity Drift                 ±0.5            %     % of sensitivity at 25°C 

  25°C to Tmin or Tmax                                                            

                                                                                  

 Zero G Drift                      ±0.2            g     Repeatable,              

                                                          can be compensated      

  25°C to Tmin or Tmax                                                            

                                                                                  

 Alignment                         ±2.0         degrees  Deviation from ideal,    

                                                          can be compensated      

                                                                                  

 Transverse Sensitivity            0.25            %     Inherent sensor error,   

                                                          excluding misalignment  

                                                                                  

 Nonlinearity                       0.2          % FSR   Best fit straight line   

                                                                                  

 Upper Cutoff Frequency        1¹  1000¹ 10000¹    Hz    ±10%, user configurable  

                                                                                  

 Noise Density                    0.225  0.325     mg    4 Hz to 1 kHz            

                                                sqrt(Hz)                          

                                                                                  

 Noise Amplitude                   2.25          mg rms  DC to 100Hz              

                                                                                  

Temperature Sensor                                                                

 Range                       -55           125    °C                              

 Resolution                        0.25           °C                              

 Accuracy                            ±2     ±3    °C     Ta = -40 to 85°C         

                                                                                  

Digital Signal Processor                                                          

 Internal Word Size                         32    bits                            

 Sensor Scan Rate                        42500     Hz    User configurable        

                                                                                  

Analog Outputs                                                                    

 Voltage Swing              0.25          4.75     V     Iout = 5 mA              

 Impedance to Analog-        100    130    220    Ohm                             

 Nonlinearity                             0.15   % FSR   Excluding sensor         

                                                          nonlinearity            

                                                                                  

Digital Output Word Size                    16    bits   Filtered, gained and     

                                                          calibration corrected   

                                                                                  

IRIG-106 PCM Output Rate                     3  Mbit/sec Based on NRZ,            

                                                          user configurable       

                                                                                  

Power Supply (Vs)                                                                 

 Input voltage limits        -20            +60    V     -20 V continuous,        

                                                          >30V if <100ms,duty <1% 

 Input voltage - operating    +8            +30    V                              

 Input current                       50            mA                             

 Rejection Ratio              80    120            dB    DC                       

                                                                                  

Temperature Range (Ta)       -40            +85   °C                              

                                                                                  

Shock survival                                                                    

 Powered                    -500           +500    g     Any axis for 0.5 ms,     

                                                          Recovers on power cycle 

 Unpowered                 -1000          +1000    g     Any axis for 0.5 ms      

                                                                                  

Mass                                 78          grams                            

                                                                                  

 ¹ User configurable low-pass filter 3dB cutoff (number poles configurable)       


Mechanical

[Platinum Series Smart Accelemeter System Dimensions]

Connections

[Platinum Series Smart Accelerometer System Connectors]

 

 Pin       1        2        3        4       5       6       7       8       9    

 Signal Analog1+ Analog2+ Analog3+ Signal-  RS485-  RS485+   Aux     +Vs     Gnd   

 Wire    Brown     Red     Orange  Yellow   Green    Blue   Violet   Grey   White  

1/2/35203A Data Sheet

Level

Instrument Hire

Gyros, Accelerometers & IMU'S

Gas Detectors

Test & Calibration Air Flow & Environmental Chart Recorders

Terms & Conditions

news / new products

links

Measurement, Control & Data Acquisition
 
 

Request a Quotation
Click here to send us your inquiry for our immediate attention

Or call us now on
+44 (0)8700 434040

Call us free on Skype:
omni-info

 

Order a Catalogue

Download our free engineering
 units converter !

 

UK / Europe Office
Tel +44 (0)8700 43 40 40
Fax +44 (0)8700 43 40 45

info@omniinstruments.co.uk

East Kingsway Business Centre
Mid Craigie Trading Estate,
Mid Craigie Rd, Dundee,
DD4 7RH, Scotland, UK
 
 
USA / Canada Office
Tel +1-866-849-3441
Fax +1 866 628 8055
info@omniinstruments.net
www.omniinstruments.net
 
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au

www.omniinstruments.com.au


we also accept purchasing cards