Measurement, Control & Data Acquisition
 
 

Request a Quotation
Click here to send us your inquiry for our immediate attention

Or call us now on
+44 (0)8700 434040

Call us free on Skype:
omni-info

 

Order a Catalogue

Download our free engineering
 units converter !

 

UK / Europe Office
Tel +44 (0)8700 43 40 40
Fax +44 (0)8700 43 40 45

info@omniinstruments.co.uk

East Kingsway Business Centre
Mid Craigie Trading Estate,
Mid Craigie Rd, Dundee,
DD4 7RH, Scotland, UK
 
 
USA / Canada Office
Tel +1-866-849-3441
Fax +1 866 628 8055
info@omniinstruments.net
www.omniinstruments.net
 
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au

www.omniinstruments.com.au


we also accept purchasing cards

 

Level

Instrument Hire

Gyros, Accelerometers & IMU'S

Gas Detectors

Test & Calibration Air Flow & Environmental Chart Recorders

Terms & Conditions

news / new products

links

13200B Single Axis MEMS Accelerometer

Rugged ±10 g to ±40 g
Uniaxial Accelerometer with Signal Conditioning and Temperature Sensor

Technical Data*

Simplify Acceleration and Temperature Measurements

[Picture of 13200B Uniaxial Accelerometer]

The Summit Instruments 13200B accelerometer includes a temperature sensor in its small rugged package. The small size and built-in power regulation allow the 13200B to fit where other accelerometers can't. A power source of +8 to +30 VDC is all that is required to measure temperature and ±10 g, ±15 g, ±20 g, ±25 g, ±30 g, or ±40 g accelerations on each of two axes.

When extra precision is required, the high repeatability of the built-in temperature allows precise compensation of temperature effects and alignment data provided on the optional calibration certificate can be used to compensate for transverse sensitivity and alignment errors.

Tested over the -40 to +85°C temperature range, the accelerometer has a nominal full scale output swing of ±2 volts. The zero g output level is nominally ±+2.5 volts. Precise values for each axis are provided on the optional calibration certificate. Custom versions of the 13200B can be provided for applications which require different ranges and/or bandwidths.

Features and Benefits

  • High Accuracy and Linearity over Wide Temperature Range
    The voltage output for the 13200B is directly proportional to the acceleration along the axis. The DC-coupled output is fully scaled, referenced, and temperature compensated. Accuracy is improved by minimizing variations due to temperature and aging effects, resulting in a sensor that is more stable over temperature than piezoelectric or piezoresistive devices. Critical applications can use the built-in temperature sensor to compensate for residual temperature effects.
  • Calibration Certificate
    Each 13200B can be supplied with an optional calibration certificate listing gain, offset, and on-axis and transverse alignment parameters needed to ensure rapid and efficient system implementation. The alignment data can be used to compensate the measured values if needed.
  • Self-Test on Digital Command
    A TTL-compatible self-test input causes a simulated acceleration to be injected into the accelerometer to verify channel integrity.
  • Small Size
    Complete conditioned uniaxial accelerometer in less than a cubic inch.
  • Built-in Power Supply Regulation
    Unregulated DC power from +8 to +30 volts is all that is required to measure accelerations. The 13200B is ideal for automotive applications with the ability to survive both continuous reverse battery to -20V and load dump transients to +60V.
  • Easy installation
    Built-in terminal block or cable with 9-pin connector makes it easy to wire the 13200B. Two through holes and four tapped holes simplify mounting.
  • Suitable for Harsh Environments
    The 13200B is robust and can be used in harsh environments. The unit will survive 500 g powered and 1000 g unpowered.

Specifications

 

Ta = Tmin to Tmax, 8 <= Vs <= 30 V, Acceleration = 0 g, unless otherwise noted.   

                                                                                  

Parameter                    Min    Typ    Max   Units   Conditions/Notes          

                                                                                  

Range                                                                             

 Measurement Full Scale       ±10           ±40    g     Must specify via -Rnnn   

 Shock survival, powered     -500          +500    g     Any axis for 0.5 ms      

                                                          Recovers on power cycle 

 Shock survival, unpowered  -2000         +2000    g     Any axis for 0.5 ms      

                                                                                  

Sensitivity                                                                       

 At 25°C, ±40 g FSR                  56¹          mV/g   Precise values on        

                                                          -C001 cal certificate   

 Drift Tmin to Tmax                 ±0.5           %     % of sensitivity at 25°C 

                                                                                  

Zero G Bias Level                                                                 

 At 25°C                      2.1           2.9    V     Precise values on        

                                                          -C001 cal certificate   

 Drift Tmin to Tmax                 ±0.2           g     Repeatable,              

                                                          can be compensated      

Alignment                                                Precise values on        

                                                          -C001 cal certificate   

 Deviation from ideal axes          ±2.0   ±3.0 degrees  Can be compensated       

                                                                                  

Transverse Sensitivity              0.25           %     Inherent sensor error,   

                                                          excluding misalignment  

Nonlinearity                         0.2         % FSR   Best fit straight line   

Upper Cutoff Frequency        4.6          1000    Hz    ±10% Must specify -Bnnn  

Noise                                                                             

 Density                               1    2.5    mg    10 Hz to 1 kHz           

                                                sqrt(Hz)                          

 Amplitude DC to 100Hz                10         mg rms                           

                                                                                  

Self Test Input Impedance      30     50          kOhm   To ground                

                                                                                  

Temperature Sensor                                       Precise values on        

                                                          -C002 cal certificate   

 Sensitivity                        8.25         mV/°K   Vt at -40°C = 1.92V nom; 

                                                          Vt at +85°C = 3.16V nom 

 Repeatability                             ±0.1   °C     At 25°C after            

                                                          temperature cycle       

 Long term drift                           ±0.1   °C                              

 Absolute error                              ±3   °C     25°C offset removed      

                                                          (±5°C uncorrected)      

Outputs                                                                           

 Voltage Swing               0.05          4.95    V     Iout = ±0.5 mA           

 Capacitive Drive Capability 1000                  pF                             

                                                                                  

Power Supply (Vs)                                                                 

 Input voltage limits         -20           +60    V     -20V continuous,         

                                                          >30V if <100ms,duty <1% 

 Input voltage - operating     +8           +30    V                              

 Input current                         6      9    mA    No load, quiescent       

 Rejection Ratio               80    120           dB    DC                       

                                                                                  

Temperature Range (Ta)        -40           +85   °C     Terminal block -T000     

                                                          rated to -30°C          

                                                                                  

Mass                                  35         grams   Precise value on         

                                                          -C001 cal certificate   

                                                                                  

 ¹Scale linearly with range option Rnnn.                                          


Mechanical

[13200B Uniaxial Accelemeter Dimensions]

Connections

[13200B Uniaxial Accelemeter Connector]

 

 Pin        1       2       3       4       5       6       7       8        9    

 Signal  Unused  Signal-   T+    +5VOut    A1+   Signal- SelfTest  +Vs      Gnd   

 Wire     Brown    Red   Orange  Yellow   Green   Blue    Violet   Grey    White  
 
13200B Data Sheet

Level

Instrument Hire

Gyros, Accelerometers & IMU'S

Gas Detectors

Test & Calibration Air Flow & Environmental Chart Recorders

Terms & Conditions

news / new products

links

Measurement, Control & Data Acquisition
 
 

Request a Quotation
Click here to send us your inquiry for our immediate attention

Or call us now on
+44 (0)8700 434040

Call us free on Skype:
omni-info

 

Order a Catalogue

Download our free engineering
 units converter !

 

UK / Europe Office
Tel +44 (0)8700 43 40 40
Fax +44 (0)8700 43 40 45

info@omniinstruments.co.uk

East Kingsway Business Centre
Mid Craigie Trading Estate,
Mid Craigie Rd, Dundee,
DD4 7RH, Scotland, UK
 
 
USA / Canada Office
Tel +1-866-849-3441
Fax +1 866 628 8055
info@omniinstruments.net
www.omniinstruments.net
 
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au

www.omniinstruments.com.au


we also accept purchasing cards