Measurement, Control & Data Acquisition
 
 

Request a Quotation
Click here to send us your inquiry for our immediate attention

Or call us now on
+44 (0)8700 434040

Call us free on Skype:
omni-info

 

Order a Catalogue

Download our free engineering
 units converter !

 

UK / Europe Office
Tel +44 (0)8700 43 40 40
Fax +44 (0)8700 43 40 45

info@omniinstruments.co.uk

East Kingsway Business Centre
Mid Craigie Trading Estate,
Mid Craigie Rd, Dundee,
DD4 7RH, Scotland, UK
 
 
USA / Canada Office
Tel +1-866-849-3441
Fax +1 866 628 8055
info@omniinstruments.net
www.omniinstruments.net
 
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au

www.omniinstruments.com.au


we also accept purchasing cards

 

Level

Instrument Hire

Gyros, Accelerometers & IMU'S

Gas Detectors

Test & Calibration Air Flow & Environmental Chart Recorders

Terms & Conditions

news / new products

links

Industrial Type Turbine Flowmeter
  • Available in a wide variety of body sizes and styles, all NT flowmeters possess an electrical pulse output directly proportional to flowrate, based upon the operating principle described in this publication.
  • The range is available on short deliveries, and popular sizes are held ex-stock
  • Available in a wide variety of body sizes and styles, all NT flowmeters possess an electrical pulse output directly proportional to flowrate, based upon the operating principle described in this publication.
  • Remote flowrate indication, alarms, totalising and batch control functions are available utilising our wide range of secondary electronic instruments.
  • Contact parts are produced from 316 stainless steel,except rotors which must possess good magnetic qualities, and here 431 stainless is used or Ferralium alloy depending upon the corrosive properties of the liquid.
  • Standard end connections are screwed BSP parallel thread with included 30 degree internal cones to BS5200, but Ermeto threads are also available.
  • Flanged meters are normally to ANSI 150 orBS4504 (DIN) standards, but older type flanges to BS10 tables D-H may also be fitted.
  • A unique feature of the design is the use of helically milled rotors cut from solid in sizes up to 65mm.
  • Bearing bushes are of PTFE/Carbon HY49 or similar, or tungsten carbide depending upon the nature of the metered fluid. In all cases, the spindle is of tungsten carbide with Cobalt binder, and thrust balls of tungsten carbide. Stainless steel ball races are used in the smaller sizes.
  • The electrical signal is a sinusoidal pulse of minimum height 50mV peak at lowest flowrate, rising to 800mV peak at max flowrate. For normal transmission distances pre-amplifiers are not essential since pulse shaping and conditioning are carried out in the appropriate electronic readout unit. In cases where heavy electrical noise is present or where transmission distances are over 500 metres, pre-amplifiers of standard or intrinsically safe design are available as head mounted weatherproof units and loop powered.
Click here to download the PDF file for full details.
Industrial type Turbine Flowmeter
PRICE LIST
Size RANGE Flanges Screwed
£ £
NT 3 0.5-5 £791.62 £659.02
NT 5 1.0-10 £791.62 £659.02
NT 7 2.0-20 £791.62 £659.02
NT 11 5-50 £771.73 £625.87
NT 13 8-80 £771.73 £625.87
NT 19 15-150 £808.86 £656.37
NT 24 25-250 £828.75 £676.26
NT 32 45-450 £946.76 £761.12
NT 38 65-650 £946.76 £761.12
NT 48 110-1100 £1,067.43 £868.53
NT 65 200-2000 £1,636.28 £1,359.15
NT 80 300-3000 £2,303.26 N/A
NT 100 500-5000 £2,591.00 N/A
NT 150 1000-10000 £2,950.35 N/A
£
BNO 250 2-20 £774.38
BNO 500L 6-60 £774.38
BNO 500 9-90 £774.38
BNO 1000 18-180 £788.97
BNO 1500 25-250 £820.79
BNO 2000 45-450 £891.07
BNO 36 65-650 £962.68
BNO 50 90-900 £1,193.40
BNO 65 120-1200 £1,621.70
£ £
NS 500 £709.41 £635.15
For ANSI 300 flanges add 7.1/2%; ANSI 600, 12.1/2%;ANSI 900, 17.1/2%
ASA 2500 25%
Additions- £
Mounting Stem for F series and 100 series displays £31.93
ATEX I.S. Pick off coil £70.18
Extra pick off coil position not incl. coil £43.40
Weatherproof coil box, inc. boss £74.00
Extra calibration ie. reverse direction £127.55
Tapered NPT Threads £40.85
Spare standard coil (max 150 Deg C) £59.98
Spare Hi temp coil (250 Deg C) £141.58
Spare hi temp coil (400 Deg C) £391.48
Spare ATEX I.S. Pick off coil £127.55
Spare amphenol connector £16.63

Issue 1 May 2003

 

Click here to download the PDF file for full details.

 

Level

Instrument Hire

Gyros, Accelerometers & IMU'S

Gas Detectors

Test & Calibration Air Flow & Environmental Chart Recorders

Terms & Conditions

news / new products

links

Measurement, Control & Data Acquisition
 
 

Request a Quotation
Click here to send us your inquiry for our immediate attention

Or call us now on
+44 (0)8700 434040

Call us free on Skype:
omni-info

 

Order a Catalogue

Download our free engineering
 units converter !

 

UK / Europe Office
Tel +44 (0)8700 43 40 40
Fax +44 (0)8700 43 40 45

info@omniinstruments.co.uk

East Kingsway Business Centre
Mid Craigie Trading Estate,
Mid Craigie Rd, Dundee,
DD4 7RH, Scotland, UK
 
 
USA / Canada Office
Tel +1-866-849-3441
Fax +1 866 628 8055
info@omniinstruments.net
www.omniinstruments.net
 
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au

www.omniinstruments.com.au


we also accept purchasing cards